NDR-120 is one economical slim 120w DIN rail power supply series, adapt to be installed on TS-35/7 .5 or TS-35/ 15 mounting rails .
NDR-120 is one economical slim 120w DIN rail power supply series, adapt to be installed on TS-35/7 .5 or TS-35/ 15 mounting rails .
Features
● Universal AC input / Full range
● protections: Short circuit / overload / over voltage / over temperature
● Cooling by free air convection
● Can be installed on DIN rail TS-35/7.5 or 15
● UL 508 (industrial control equipment) approved
● BS EN/EN61000-6-2(BS EN/EN50082-2) industrial immunity level .100% full load burn-in test
● 3 years warranty
Applications
● Industrial control system
● Semiconductor fabrication equipment
● Factory automation
● Electro-mechanical apparatus
NDR-120 is one economical slim 120w DIN rail power supply series, adapt to be installed on TS-35/7 .5 or TS-35/ 15 mounting rails . The body is designed 40mm in width , which allows space saving inside the cabinets . The entire series adopts the full range AC input from 90VAC to 264VAC and conforms to BS EN/EN61000-3-2, the norm the European Union regulates for harmonic current.
NDR-120 is designed with metal housing that enhances the unit's power dissipation. with working efficiency up to 89%, the entire series can operate at the ambient temperature between -20℃ and 70℃ under air convection . It is equipped with constant current mode for over-load protection , fitting various inductive or capacitive applications . The complete protection functions and relevant certificates for industrial control apparatus (UL508, TUV BS EN/EN62368-1, and etc .) make NDR-120 a very competitive power supply solution for industrial applications .
MODEL |
NDR-120-12 |
NDR-120-24 |
NDR-120-48 |
|
OUTPUT |
DC VOLTAGE |
12V |
24V |
48V |
RATED CURRENT |
10A |
5A |
2.5A |
|
CURRENT RANGE |
0 ~ 10A |
0 ~ 5A |
0 ~ 2.5A |
|
RATED POWER |
120W |
120W |
120W |
|
RIPPLE & NOISE (max.) Note.2 |
100mVp-p |
120mVp-p |
150mVp-p |
|
VOLTAGE ADJ. RANGE |
12 ~ 14V |
24 ~ 28V |
48 ~ 55V |
|
VOLTAGE TOLERANCE Note.3 |
±2.0% |
±1.0% |
±1.0% |
|
LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
|
LOAD REGULATION |
±1.0% |
±1.0% |
±1.0% |
|
SETUP, RISE TIME |
1200ms, 60ms/230VAC 2500ms, 60ms/115VAC at full load |
|||
HOLDUP TIME (Typ.) |
16ms/230VAC 10ms/115VAC at full load |
|||
INPUT |
VOLTAGE RANGE Note.6 |
90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)] |
||
FREQUENCY RANGE |
47 ~ 63Hz |
|||
EFFICIENCY (Typ.) |
85.5% |
88% |
89% |
|
AC CURRENT (Typ.) |
2.25A/115VAC 1.3A/230VAC |
|||
INRUSH CURRENT (Typ.) |
20A/115VAC 35A/230VAC |
|||
LEAKAGE CURRENT |
<1mA / 240VAC |
|||
PROTECTION |
OVERLOAD |
105 ~ 130% rated output power |
||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
||||
OVER VOLTAGE |
14 ~ 17V |
29 ~ 33V |
56 ~ 65V |
|
Protection type : Shutdown o/p voltage, re-power on to recover |
||||
OVER TEMPERATURE |
Shutdown o/p voltage, re-power on to recover |
|||
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +70℃ (Refer to "Derating Curve") |
||
WORKING HUMIDITY |
20 ~ 95% RH non-condensing |
|||
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH |
|||
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) |
|||
VIBRATION |
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
|||
SAFETY & EMC (Note 4) |
SAFETY STARDS |
UL508, TUVBSEN/EN62368-1, EACTPTC 004 approved;(meet BSEN/EN60204-1) |
||
WITHST VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
|||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH |
|||
EMC EMISSION |
Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 |
|||
EMC IMMUNITY |
Compliance to BS EN/EN61000-4-2,3,4,5,6,8, 11, BS EN/EN55024, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN61204-3, heavy industry level, EAC TP TC 020 |
|||
OTHERS |
MTBF |
2636.8K hrs min. Telcordia SR-332 (Bellcore) ; 453.3K hrs min. MIL-HDBK-217F (25℃) |
||
DIMENSION |
40* 125.2* 113.5mm (W*H*D) |
|||
PACKING |
0.6Kg; 20pcs/13Kg/1. 16CUFT |
|||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. 6. Derating may be needed under low input voltage. please check the derating curve for more details. 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). ※ product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |