NDR-75 is one economical slim 75w Din rail power supply series, adapt to be installed on TS-35/7 .5 or TS-35/ 15 mounting rails . The body is designed 32mm in width ,
NDR-75 is one economical slim 75w Din rail power supply series, adapt to be installed on TS-35/7 .5 or TS-35/ 15 mounting rails . The body is designed 32mm in width ,
Features
● Universal AC input / Full range
● protections: Short circuit / overload / over voltage / over temperature
● Cooling by free air convection
● Can be installed on DIN rail TS-35/7.5 or 15
● UL 508 (industrial control equipment) approved
● EN61000-6-2(EN50082-2) industrial immunity level
● 100% full load burn-in test
● 3 years warranty
Applications
● Industrial control system
● Semiconductor fabrication equipment
● Factory automation
● Electro-mechanical apparatus
NDR-75 is one economical slim 75w Din rail power supply series, adapt to be installed on TS-35/7 .5 or TS-35/ 15 mounting rails . The body is designed 32mm in width , which allows space saving inside the cabinets . The entire series adopts the full range AC input from 90VAC to 264VAC and conforms to EN61000-3-2, the norm the European Union regulates for harmonic current.
NDR-75 is designed with metal housing that enhances the unit's power dissipation . with working efficiency up to 89%, the entire series can operate at the ambient temperature between -20℃ and 70℃ under air convection . It is equipped with constant current mode for over-load protection , fitting various inductive or capacitive applications . The complete protection functions and relevant certificates for industrial control apparatus (UL508, TUV EN60950-1, and etc .) make NDR-75 a very competitive power supply solution for industrial applications .
MODEL |
NDR-75-12 |
NDR-75-24 |
NDR-75-48 |
|
OUTPUT |
DC VOLTAGE |
12V |
24V |
48V |
RATED CURRENT |
6.3A |
3.2A |
1.6A |
|
CURRENT RANGE |
0 ~ 6.3A |
0 ~ 3.2A |
0 ~ 1.6A |
|
RATED POWER |
75.6W |
76.8W |
76.8W |
|
RIPPLE & NOISE (max.) Note.2 |
80mVp-p |
120mVp-p |
150mVp-p |
|
VOLTAGE ADJ. RANGE |
12 ~ 14V |
24 ~ 28V |
48 ~ 55V |
|
VOLTAGE TOLERANCE Note.3 |
±2 .0% |
±1 .0% |
±1 .0% |
|
LINE REGULATION |
±0 .5% |
±0 .5% |
±0 .5% |
|
LOAD REGULATION |
±1 .0% |
±1 .0% |
±1 .0% |
|
SETUP, RISE TIME |
1200ms , 60ms/230VAC 2000ms , 60ms/115VAC at full load |
|||
HOLD UP TIME (Typ.) |
60ms/230VAC 12ms/115VAC at full load |
|||
INPUT |
VOLTAGE RANGE Note.6 |
90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+) , AC/N(-)] |
||
FREQUENCY RANGE |
47 ~ 63Hz |
|||
EFFICIENCY (Typ.) |
85.5% |
88% |
89% |
|
AC CURRENT (Typ.) |
1.45A/115VAC 0.9A/230VAC |
|||
INRUSH CURRENT (Typ.) |
20A/115VAC 35A/230VAC |
|||
LEAKAGE CURRENT |
<1mA / 240VAC |
|||
PROTECTION |
OVERLOAD |
105 ~ 130% rated output power |
||
Protection type : Constant current limiting , recovers automatically after fault condition is removed |
||||
OVER VOLTAGE |
14 ~ 17V |
29 ~ 33V |
56 ~ 65V |
|
Protection type : Shut down o/p voltage , re-power on to recover |
||||
OVER TEMPERATURE |
Protection type : Shut down o/p voltage , re-power on to recover |
|||
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +70℃ (Refer to "Derating Curve") |
||
WORKING HUMIDITY |
20 ~ 95% RH non-condensing |
|||
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH |
|||
TEMP. COEFFICIENT |
±0 .03%/℃ (0 ~ 50℃, |
|||
VIBRATION |
Component:10 ~ 500Hz , 2G 10min./1cycle , 60min. each along X , Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
|||
SAFETY & EMC (Note 4) |
SAFETY STARDS |
UL508 , TUV EN60950-1 , EACTPTC 004 approved;(meet EN60204-1) |
||
WITHST VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0 .5KVAC |
|||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG , O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH |
|||
EMC EMISSION |
Compliance to EN55032 (CISPR32) , EN61204-3 Class B , EN61000-3-2 ,-3 , EAC TP TC 020 |
|||
EMC IMMUNITY |
Compliance to EN61000-4-2 ,3 ,4 ,5 ,6 ,8 , 11 , EN55024 , EN61000-6-2 (EN50082-2) , EN61204-3 , heavy industry level , criteria A , EAC TP TC 020 |
|||
OTHERS |
MTBF |
486.2K hrs min. MIL-HDBK-217F (25℃) |
||
DIMENSION |
32* 125.2* 102mm (W*H*D) |
|||
PACKING |
0.51Kg; 28pcs/15 .3Kg/1 .22CUFT |
|||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. 6. Derating may be needed under low input voltage. please check the derating curve for more details. 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). |
Ordering Information |
---|
Date | Version | Description | Download |
---|---|---|---|
2024-09-18 | V1.0 | 75W Single Output Industrial DIN RAIL | |
2024-09-18 | V1.0 | 75W Single Output Industrial DIN RAIL | |
2024-09-18 | V1.0 | 75W Single Output Industrial DIN RAIL | |
2024-09-18 | V1.0 | 75W Single Output Industrial DIN RAIL | |
Photo | Model | Description |
---|